CO₂ Laser Tube Cooling Equipment Selection and Installation Requirements

CO₂ Laser Tube Cooling Equipment Selection and Installation Requirements

CO₂ Laser Tube Cooling Equipment Selection and Installation Requirements

Water cooling equipment is essential for the proper operation of CO₂ laser tubes (hereinafter referred to as "laser tubes"). Selecting unsuitable cooling equipment may cause laser tube rupture, electrical breakdown, unstable output power, abnormal beam spots, and other failures.

To ensure reliable laser tube operation and prevent cooling-related problems, follow the equipment selection and installation requirements below.

1. Select Suitable Water Cooling Equipment

Choose the appropriate water chiller or cooling equipment according to the laser tube model and power requirements.

- Models 1400T7, 1600S7, 1600F7 (C6), 1700H7 (C7), and 1800W7 (C8): Select a water chiller with active cooling capability, such as CW-5000, CW-5200, or DIC004.

- Models 1800U7 (C9), 2000K7 (C20), and other high-power laser tubes: Select a water chiller with stronger cooling capacity, such as CW-5300, CW-6000, or DIC005.

- Other laser tubes rated at 80W or below: Select suitable cooling equipment according to the application and operating conditions. Options include CW-3000, DIC002, or a water pump.

2. Install a Water Protection Switch

If the water chiller does not have a built-in water flow protection function, a separate water protection switch must be installed at the water inlet of each laser tube.

If the water chiller has a built-in water protection function, its water protection signal can be used directly.

The water protection switch or water chiller protection signal must be connected to the laser power supply. This ensures that the laser power supply automatically stops laser emission if a cooling system failure occurs.

3. Cooling System Configuration for Two Laser Tubes

When one water chiller supplies cooling water to two laser tubes, the following requirements must be observed:

  • If the water chiller has only one water protection switch, install a separate water protection switch at the water inlet of each laser tube.

  • If the water chiller has two independent water protection switches installed at the respective water outlets, its protection signals can be used directly.

4. Avoid Overloading the Water Chiller

  • Avoid using a water chiller with only one inlet and one outlet to supply cooling water to two laser tubes whenever possible.

  • One water chiller must not supply cooling water to three or more laser tubes simultaneously, unless it is a specially customized chiller designed for this purpose.

5. Regular Cleaning and Water Replacement

Clean the water cooling equipment regularly and replace the circulating cooling water as necessary.

Prevent dirt, deposits, and other contaminants from accumulating inside the cooling pipes, water pump, and laser tube cooling channels. Blockages can restrict water circulation and cause overheating or damage to the laser tube.

Important: Always select cooling equipment according to the laser tube manufacturer's recommended cooling capacity, water flow rate, and operating temperature. Ensure that the water protection signal is correctly connected and tested before operating the laser machine.

Recomendado

Ver todos los artículos
Manual de funcionamiento del tubo láser CO₂

Manual de funcionamiento del tubo láser CO₂

El manual de funcionamiento de los tubos láser HANLEI CO₂ proporciona instrucciones esenciales para la instalación, el funcionamiento y el mantenimiento de los tubos láser CO₂ . Incluye información sobre conexiones eléctricas, protección contra alta tensión, requisitos del sistema de refrigeración, ajustes de corriente de funcionamiento, precauciones de seguridad, mantenimiento rutinario y procedimientos comunes para la resolución de problemas.

Conexión y protección de cable de alta tensión para tubo láser CO₂

Conexión y protección de cable de alta tensión para tubo láser CO₂

Un cableado de alta tensión adecuado y una protección de aislamiento correcta son esenciales para el funcionamiento seguro y estable de los tubos láser CO₂ . Esta guía presenta las conexiones de cables de alta tensión, los requisitos de aislamiento, el enrutamiento de cables, la conexión a tierra y las medidas de protección para reducir los arcos eléctricos, las fugas y los daños por alta tensión.