HANLEI CO₂ Laser Cutting Machine
Daily Maintenance and Troubleshooting
The stable and reliable operation of the machine depends on correct operating procedures and regular daily maintenance. This section describes the recommended maintenance procedures and common troubleshooting methods.
1. Daily Maintenance
1.1 Water Replacement and Water Tank Cleaning
Recommended frequency: Clean the water tank and replace the circulating water once a week.
Important: Before operating the machine, make sure the laser tube is completely filled with circulating water. Water quality and temperature directly affect the service life of the laser tube.
Use purified water as the circulating coolant.
Keep the water temperature below 35°C.
If the water temperature exceeds 35°C, replace the circulating water or take appropriate measures to reduce the temperature.
A dedicated industrial water chiller is recommended. Alternatively, two water tanks may be used where appropriate.
Water Tank Cleaning Procedure:
Turn off the machine and disconnect the power supply.
Disconnect the water inlet hose and allow the water inside the laser tube to drain back into the water tank.
Open the water tank and remove the water pump.
Clean any dirt or deposits from the water pump.
Thoroughly clean the water tank and refill it with fresh circulating water.
Reinstall the water pump in the tank.
Reconnect the pump hose to the water inlet and check all hose connections.
Power the water pump separately and allow it to run for 2–3 minutes to ensure that the laser tube is completely filled with circulating water.
1.2 Exhaust Fan Cleaning
Prolonged operation can cause dust and solid particles to accumulate inside the exhaust fan. This may increase operating noise and reduce exhaust efficiency.
If the fan has insufficient suction or poor fume extraction, clean it as follows:
Turn off the machine and disconnect the power supply.
Remove the air inlet and outlet ducts from the fan.
Remove accumulated dust from inside the ducts.
Carefully turn the fan upside down and rotate the fan blades by hand to remove accumulated dust.
Reinstall the fan and reconnect the ducts securely.
1.3 Lens Cleaning
Recommended frequency: Clean the lenses before daily operation. The machine must be switched off before cleaning.
The laser cutting machine generally has three reflective mirrors and one focusing lens:
Mirror No. 1: Located at the laser tube output, usually in the upper-left area of the machine.
Mirror No. 2: Located at the left end of the gantry beam.
Mirror No. 3: Located at the top of the laser head mounting assembly.
Focusing Lens: Located inside the adjustable lens barrel at the lower part of the laser head.
The laser beam is reflected and focused through these optical components before being emitted from the laser head.
Dust and other contaminants on the lens surfaces can reduce laser transmission efficiency and may damage the optical coatings.
Cleaning Procedure:
Mirrors No. 1 and No. 2 do not normally need to be removed. Use optical lens tissue lightly moistened with an appropriate lens-cleaning solution.
Gently wipe from the center of the lens toward the outer edge in a circular motion.
Mirror No. 3 and the focusing lens may need to be removed from their holders for cleaning. Follow the machine-specific optical assembly instructions.
Clean these lenses using the same method.
Reinstall all optical components in their original positions and check that they are correctly seated.
Important Precautions:
Handle optical components carefully. Do not scratch or damage their coated surfaces.
Avoid applying excessive pressure when cleaning.
Handle lenses gently to prevent them from falling.
When reinstalling the focusing lens, make sure the concave surface faces downward, as specified for this machine's optical assembly.
Optical components should only be removed or adjusted by trained personnel.
1.4 Guide Rail Cleaning and Lubrication
Recommended frequency: Clean every two weeks. The machine must be switched off before maintenance.
Required materials: Clean, dry cotton cloth and suitable lubricating oil.
Linear Guide Rail Cleaning
Move the laser head to the far-right or far-left side of the machine.
Locate the linear guide rail.
Wipe the rail with a clean, dry cotton cloth until it is free of visible dust.
Apply a small amount of suitable lubricant, such as sewing machine oil, if specified for the guide rail.
Slowly move the laser head from side to side several times to distribute the lubricant evenly.
Roller Guide Rail Cleaning
Move the gantry beam toward the inside of the machine.
Open the end covers on both sides of the machine.
Locate the guide rails and roller contact surfaces.
Use a clean, dry cotton cloth to remove dust and debris from both sides of the rails and the roller contact areas.
Move the gantry beam to access and clean the remaining sections.
1.5 Optical Path Inspection
The laser optical path system consists of reflective mirrors and a focusing lens. The mirrors redirect the laser beam, while the focusing lens concentrates it onto the material.
The focusing lens is installed in a fixed optical assembly, while the three reflective mirrors are mounted on mechanical supports. Mechanical vibration or movement may cause mirror alignment to shift.
Although optical misalignment is not common under normal operating conditions, users are advised to inspect the optical path before each operation.
If the laser beam is not correctly aligned, have the optical path checked and adjusted by trained service personnel.
2. Common Faults and Troubleshooting
| No. | Fault Symptom | Possible Cause / Inspection Method | Recommended Solution |
|---|---|---|---|
| 1 | The machine does not respond after startup. | 1. Check whether the machine is receiving power. 2. Check whether the mainboard parameters are configured correctly. | 1. Reconnect the cables and connectors. 2. Refer to the software user manual and correct the parameters. |
| 2 | The laser fires continuously after startup. | 1. Check whether the mainboard parameters are configured correctly. | 1. Refer to the software user manual and correct the laser output parameters. |
| 3 | The machine does not reset correctly after startup. | 1. Check whether the mainboard parameters are configured correctly. | 1. Refer to the software user manual and correct the reset direction or axis polarity settings. |
| 4 | The laser output is intermittent during operation. | 1. Check whether the water circulation system is operating smoothly. 2. Check whether the power supply voltage is stable. | 1. Clean the water tank and water pump, and clear any blocked water pipes. 2. Install a suitable voltage stabilizer if required. |
| 5 | The processed graphic dimensions do not match the design. | 1. Check whether BMP files are exported from CorelDRAW at a 1:1 scale. 2. When exporting BMP files from CorelDRAW 9.0, check whether the total pixel count is greater than or equal to 10,000. 3. When exporting PLT files from CorelDRAW 9.0, check whether the scaling option in the HPGL export dialog is set to 100%. 4. Check whether the resolution settings on the mainboard are correct. | 1. Set the graphic scale to 1:1. 2. Adjust the resolution to reduce the total pixel count to below 10,000. 3. Set the scaling option to 100%. 4. Refer to the software user manual and correct the relevant parameters. |
| 6 | The computer sends data, but the machine does not operate. | 1. Check whether the correct data transmission port is selected. 2. Check whether the laser machine power switch is turned on. 3. Check whether the machine is properly grounded. 4. Check whether the driver software is installed. | 1. Select the correct communication port. 2. Turn on the machine power switch. 3. Ensure that the grounding connection is properly installed. 4. Install the USB driver. |
| 7 | No laser output during operation. | 1. Check whether the optical path is misaligned. 2. Check the water circulation system. | 1. Refer to the optical path alignment instructions or contact trained service personnel. 2. Ensure that the water circulation system is operating smoothly. |
| 8 | The laser device cannot be detected. | 1. Check for a communication fault between the computer and the USB connection. | 1. Check the computer or USB port and replace the faulty component if necessary. |
3. Maintenance and Safety Notes
Always switch off the machine and disconnect the power supply before performing routine maintenance.
Never operate the laser tube without adequate water circulation.
Keep the optical components clean and avoid touching their coated surfaces directly.
Check the exhaust system regularly to maintain effective fume extraction.
Keep guide rails clean and properly lubricated to ensure smooth machine movement.
Electrical connections, laser power supplies, and optical path adjustments must be handled by qualified personnel.
If a fault cannot be resolved using the procedures above, stop operating the machine and contact HANLEI technical support.
Manufacturer: Dongguan Hanlei Laser Equipment Technology Co., Ltd.
Brand: HANLEI